Batteries Maintenance TipsNew battery modules: why it stops at 70 % and how to fix it
This week we have had several similar questions: “We added modules to our battery, and now it never goes past 70 % during the day. It used to reach 100 %. Is something broken?” In most cases, no. An expanded battery needs a few days for the new and old modules to fall into step, and quite often an inverter setting is stopping the charge early.
Read More
Self consumption MaintenancePigeons under your solar panels: how to stop them (mesh, wires and bird scarers)
This week we were on a roof in Empuriabrava where pigeons had moved in under the solar panels. From the street you could not see a thing. But underneath there were nests, feathers and a thick layer of droppings, and the sound of feet on the roof started very early in the morning.
Read More
Self consumption MaintenanceGrowatt Error 401: what it means and how to fix it
You open the app, or walk past the inverter, and see a message you weren’t expecting: “Error 401”. The panels are still there, the sun is shining, but something isn’t right. If you have a Growatt hybrid inverter from the MIN TL-XH series, this error has a fairly specific explanation, and in many cases a simple fix.
Read More
Self consumption MaintenanceHow to tell if a panel or microinverter in your system is underperforming
One of our customers asked us a simple question: “Can I fit better optimizers? I feel like the panels could give more.” Before recommending anything, we looked at the data from his system. The surprise was that the problem wasn’t the whole installation: one of the two microinverters was producing only a third of what it should, while the other worked perfectly. For months, half of the panels had been working far below their potential, and from the outside you couldn’t tell.
Read More
Self consumption MaintenanceThe RCD trips and the solar panels stop producing: automatic reclosing
One of our customers in the Alt Empordà wrote to us, worried: his installation had not produced anything for days. When we went there, the cause was very simple: the RCD (residual-current device) on the grid side of the inverter had tripped. We switched it back on and everything worked again instantly. But the house is a second home, nobody was there to notice, and the installation sat idle for ten days.
Read More
Photovoltaics Performance MaintenanceWhy my solar panels produce less in summer
You have a photovoltaic system and, in the middle of summer, with blazing sun and a clear sky, you check the app and it produces less than you expected. Sometimes even less than on a cooler, clear spring day. You are not alone — and, above all, it is not a fault: it is physics.
Read More