The Empordà is full of houses with a flat roof or a roof terrace: holiday homes from the 1970s and 80s, seafront apartments, recent extensions. When owners start thinking about solar panels, the first question is usually the same: “Will you have to drill through the roof? I don’t want leaks.”

Not necessarily. This week we are setting up a small installation on a flat roof using concrete mounts that act as ballast: the panels are held down by weight alone, with no screw going through the waterproofing. Here we explain when this makes sense, how it is sized and what has to be checked first.

Diagram: two rows of panels on concrete blocks tilted at 18°, with the spacing between rows and the protection sheet under each block

Ballast or anchoring: when to use which

There are two ways to fix panels to a flat roof:

  • Anchoring the frame to the slab with bolts or chemical anchors. It handles wind very well, but every anchor goes through the waterproofing and has to be sealed properly. If it isn’t, it is a potential leak.
  • Ballasting: the frame rests on the roof and weight (concrete blocks, or rails loaded with paving slabs or gravel bags) stops the wind from lifting or shifting it. Nothing is drilled.

Ballast is the usual choice when:

  • the waterproofing is in good condition and you don’t want to touch it (or it is still under warranty);
  • the roof is flat and walkable, or at least firm enough to take point loads;
  • the building structure can carry the extra weight (more on this below).

Anchoring, or a mixed solution, is better when the roof can’t take much weight, when the surface is sloped, when the site is very exposed to wind (a tall building, an isolated house on a hilltop, a cliff edge) or when the waterproofing has to be redone anyway and the anchors can be built into the works.

Tilt: why 18°

In the Empordà, the tilt that gives the most energy over the year is steeper, around 35°. On a ballasted flat roof, though, lower angles such as 18° are used, for three reasons:

  1. Less wind. The steeper the panel, the more surface it offers to the wind and the more ballast it needs.
  2. Less shade. A lower panel casts a shorter shadow, so rows can be closer together.
  3. More panels on the same roof. Closer rows mean more panels fit.

The yearly loss compared with the ideal tilt is small, and on a roof with limited space it is often made up for by one extra panel.

Row spacing: so that one row doesn’t shade the next

With more than one row, the front row must not shade the one behind it. The reference criterion in Spain is the IDAE technical specification (Pliego de condiciones técnicas): the spacing must guarantee at least 4 hours of sun around midday on the winter solstice, when the sun is lowest. The formula is:

d = h / tan(61° – latitude)

where h is the height difference between the top edge of one row and the bottom edge of the next, and d is the clear horizontal distance between them. In the Empordà (latitude ≈ 42°), 1 / tan(61° – 42°) gives a factor of about 2.9: the clear gap should be roughly three times the panel’s height.

An example with a panel of about 2.3 × 1.1 m at 18°:

  • Landscape (long side parallel to the roof), the top edge sits about 35 cm above the bottom edge → leave roughly 1 m clear between rows.
  • Portrait (long side pointing up), the height difference is about 70 cm → you would need about 2 m between rows.

Landscape or portrait

On a ballasted flat roof, landscape usually wins:

  • the panel sits lower and catches less wind;
  • the shadow is shorter and rows can be closer;
  • with large panels it is often the only orientation the mount manufacturer allows.

Portrait can make sense with smaller panels, in a long narrow space, or when only one row fits. Each mount manufacturer states which panel sizes and orientations each model is approved for: check the datasheet before buying anything.

Wind and weight per panel

As far as the wind is concerned, a solar panel is a sail of about 2 to 2.6 m². In a Tramuntana, the wind can push it and, above all, try to lift it from underneath. The ballast has to be heavy enough that the frame neither lifts nor slides.

That is why manufacturers set minimum rules. For example, for the 18° concrete block we used this week (a Solarbloc-type block, cast in one piece, about 100 × 16 cm and about 60 kg):

  • each panel rests on at least 2 blocks along its long side, placed about a quarter of the way in from each end;
  • within a row, blocks can be shared by two neighbouring panels at the joint;
  • for panels 1.75 m long or more, the manufacturer makes an additional reinforcement ballast mandatory, fixed to the block according to its instructions.

Why is it mandatory for large panels? Because today’s panels (400 to 600 W) are much longer than a few years ago: more surface means more wind force, and the block’s own weight no longer leaves enough margin.

The wind is also not the same everywhere on the roof: it blows harder at the corners and edges. Where possible, keep a margin from the parapet rather than placing panels right at the edge.

Can the roof take the weight?

This is the step you cannot skip. A real, small example: 8 panels in 2 rows of 4, in landscape. Sharing blocks at the joints, that is 5 blocks per row, 10 in total: 600 kg of concrete alone, plus the reinforcement ballast and the panels (about 25–30 kg each). You quickly get close to a tonne.

Spread over the whole area the array covers, the average per square metre is moderate, but the weight is not spread evenly: it is concentrated where each block rests. A concrete slab in good condition often has the margin; a lightweight roof, a terrace on timber beams, an old roof with cracks or a floor slab you are unsure about is another story.

Our rule is simple: if there is any doubt about the structure, we ask a structural professional (architect, building surveyor or engineer) for an opinion before anything goes up. It costs far less than a repair.

Protecting the waterproofing

Not drilling doesn’t mean the roof needs no protection:

  • A protection sheet or rubber pads under every block, so the concrete doesn’t scratch or puncture the bitumen felt or membrane.
  • Keep the drains clear and don’t create ponding: the blocks must not dam rainwater.
  • Check the roof first: if the waterproofing is near the end of its life, it is better to redo it now than to take the panels down in two years.
  • Handle materials with care: a tonne of blocks, carried by hand or lifted by crane, must not be dropped or dragged across the roof.

In short

A flat roof or roof terrace is often a good place for solar panels, without drilling anything. The key is doing the numbers: a low tilt, well-spaced rows, enough ballast for the panel size and the local wind, and the certainty that the structure can carry the load.

At Sunfort Solar we assess every roof before proposing a mounting system: ballasted, anchored or mixed. If you have a house in the Empordà with a flat roof or roof terrace, get in touch and send us a few photos of the roof and the drains: we’ll tell you which solution fits. And if you already have panels and one shades another, you may find how to tell if a panel is underperforming useful.